unable to load a single Bulletin A
When attempting to load a single Bulletin A from IERS, an error is triggered.
The problem arises because Bulletin A include separate chunks of data
(rapid data,
final data, and predicted data). There are no gaps between rapid data
and predicted data,
but there is a gap between rapid data and final data. The check is not
done by the loader,
but rather at FramesFactory level where the threshold for triggering an
exception is
hard-coded to 5 Julian days.
This hard-coded value should be customizable si users willing to use e
single Bulletin A
can set it to values exceeding a few months to ensure the gap is
accepted (but of course
in this case it is user responsibility to ensure the Bulletin A used is
consistent with
the needs).
(from redmine: issue id 194, created on 2015-03-27, closed on 2016-02-10)