Wrong units in SP3 clock rate of change
The clock rate of change fields in SP3 files are in units of 10⁻⁴ microseconds/second. Orekit parses them as 10⁻⁴ seconds/second, so they are 1 million time too large.
Edited by Luc Maisonobe
The clock rate of change fields in SP3 files are in units of 10⁻⁴ microseconds/second. Orekit parses them as 10⁻⁴ seconds/second, so they are 1 million time too large.