Optimizing (Field)NumericalPropagator working with PositionAngleType
Current default PositionAngleType
is TRUE
, which is the slowest, the fastest being MEAN
as far as derivative evaluation is concerned. ECCENTRIC
might be a good compromise as it is used for conversion to position vector.
Edited by Romain Serra